SPECIFICATIONS

Standard line TX

Reference

Central Frequency
[MHz]

Active Diameter
[mm]

Overall Diameter
[mm]

Overall Length
[mm]

Focal Distance
[mm]

Divergence Half-angle
[deg]

TX05-19-23

0.5

19

23

40

30.5

4.6°

TX1-13-16

1

13

16

40

28.5

3.4°

TX2-10-13

2

10

13

40

33.8

2.2°

TX4-5-8

4

5

8

40

16.9

2.2°

TX8-2.5-8

8

2.5

8

40

8.5

2.2°

High temperature line TH

TH4-5-8

4

5

8

60

16.9

2.2°

High pressure line TP

TP4-5-8

4

5

8

60

16.9

2.2°

Focused line TF

Reference

Central Frequency
[MHz]

Active Diameter
[mm]

Overall Diameter
[mm]

Overall Length
[mm]

Natural Focal Distance
[mm]

Minimum Possible Focal Distance
[mm]

TF05-19-23

0.5

19

23

40

30.5

20.3

TF1-13-16

1

13

16

40

28.5

17.4

TF2-10-13

2

10

13

40

33.8

15.2

TF4-5-8

4

5

8

40

16.9

10.8

TF8-2.5-8

8

2.5

8

40

8.5

5.0

Note: Focused transducers can be ordered with focus point from listed minimum length up. Active element curvature point varies according to selected focus point.